Plumbing
CPVC pipes and fittings
For hot and cold water supply. Solvent-welded, temperature and pressure rated.
Overview
What CPVC is
- Use
- Hot and cold supply
- Jointing
- Solvent weld
- Common sizes
- 15–50 mm nominal
- Cement
- CPVC-specific only
CPVC pipe is used where water is under supply pressure and may be hot — the run from the tank or geyser to the taps, mixers and appliances. It is rigid, joined by solvent welding rather than threading, and connects to metal fittings through brass transition pieces.
The temperature and pressure rating is a property of the specific product, not of CPVC in general. Check the manufacturer’s figure for the pipe you are buying rather than assuming a rating.
Applications
Typical applications
- Hot and cold water supply within a building
- Geyser inlet and outlet runs
- Concealed supply lines in walls
- Bathroom and kitchen supply distribution
- Connections to taps, mixers and angle valves through brass fittings
Options
Available options
Pipes
Sold by length in the common nominal sizes. Wall thickness varies by pressure class.
Plain fittings
Solvent-weld only, no metal.
Brass transition fittings
Where CPVC meets a threaded metal connection.
Valves
Isolation within a CPVC run.
Solvent cement
CPVC-specific. Not interchangeable with UPVC or PVC cement.
Clamps & supports
Holding the run and allowing for expansion.
Comparison
How the options compare
| CPVC | UPVC | PVC | SWR | |
|---|---|---|---|---|
| Typical use | Hot & cold supply | Cold supply | Non-pressure, light duty | Soil, waste, rainwater |
| Pressure rated | Yes | Yes | Varies by product | No — gravity |
| Hot water | Yes, to product rating | No | No | No |
| Jointing | Solvent weld (CPVC cement) | Solvent weld (UPVC cement) | Solvent weld | Solvent weld or ring-fit |
| Common sizes | 15 mm to 50 mm nominal | 20 mm upward | 20 mm upward | 75 mm, 110 mm and larger |
| Cement | CPVC-specific | UPVC-specific | PVC | As specified by system |
Scroll the table sideways to see all columns.
Measurements
Important measurements
- Nominal pipe size — printed along the pipe
- Pressure class if the project specifies one
- Thread size where a brass fitting connects to a tap or valve
- Total pipe length, allowing for cuts and offcuts
- Number of each fitting type, counted from the layout
- Distance between clamps as the manufacturer specifies
Specification
What to check on the specification
- Temperature and pressure rating printed by the manufacturer
- Standard the pipe is made to
- Pressure class or SDR where stated
- Whether the brass insert is threaded to the size you need
Choosing
How to choose
- Confirm hot or cold. If hot water is anywhere on the run, CPVC is the system. If the whole run is cold, UPVC may be specified instead — check the project requirement.
- Match the size to the existing or specified layout. Nominal sizes are not interchangeable between systems. Take the size from the pipe or the drawing, not from a similar-looking fitting.
- Count the fittings from the layout. Elbows, tees and couplers add up faster than expected. Count from the run rather than estimating.
- Buy the correct cement. CPVC cement for CPVC. Using UPVC or PVC cement on CPVC produces joints that fail.
- Add transition fittings where metal is involved. Every tap, valve, geyser and meter connection needs a brass transition piece of the right thread.
Suitability
Best suited for
New supply installations
Where the whole hot and cold distribution is being run.
Geyser connections
Where the pipe carries water above ambient temperature.
Concealed work
Solvent-welded joints have no threads to loosen behind a wall.
Considerations
Worth knowing
CPVC expands and contracts with temperature more than metal. Clamp spacing and allowance for movement matter on long runs — follow the manufacturer’s figures.
Solvent-welded joints cannot be dismantled. Dry-fit the run before cementing.
Concealed pipework should be pressure-tested before it is covered. That is work for your plumber, not something a product choice substitutes for.
Compatibility
Compatibility
CPVC fittings pair with CPVC pipe of the same system and size. They are not compatible with UPVC pipe of the same nominal number, because the sizing conventions differ.
Where CPVC connects to a metal thread — a tap, a valve, a geyser — use a brass transition fitting. Threading CPVC directly against metal is not a substitute.
Price
What affects price
- Diameter
- Pressure class or wall thickness
- Brand
- Whether the fitting carries a brass insert — brass fittings cost noticeably more
- Quantity
Availability
What affects availability
- Common sizes move quickly
- Larger diameters are held in less depth
- Brass transition fittings vary by brand and thread combination
- Higher pressure classes are stocked in fewer sizes
Quotation
What to bring or send
- The nominal pipe size
- Whether hot water is involved
- A count of each fitting from your layout
- Thread sizes for any metal connections
- A photograph of the existing pipe if you are extending or repairing
Avoid
Common mistakes
- Using UPVC or PVC solvent cement on CPVC
- Assuming a CPVC fitting fits UPVC pipe of the same number
- Running CPVC to a geyser without checking the temperature rating
- Buying pipe without the transition fittings the taps will need
- Clamping too far apart on a hot run, so the pipe bows
Questions
Frequently asked
Can CPVC be used for hot water?
Yes, within the manufacturer’s stated temperature and pressure rating. That is the main reason CPVC is chosen over UPVC.
Check the rating printed on the pipe against the temperature your geyser delivers.
Is CPVC cement the same as UPVC cement?
No. They are different formulations and are not interchangeable. Using the wrong one produces a joint that may look fine and fail later.
Will a CPVC fitting fit a UPVC pipe?
Not reliably. The two systems use different sizing conventions, so the same nominal number does not mean the same dimension. Keep the system consistent.
What size CPVC do I need?
Take the size from the existing pipe or from the project drawing. Sizing a new distribution run is a design decision that depends on outlets, pressure and length — confirm it against the specification for your project rather than by comparison.